Distributed Generation Study/Patterson Farms
From Open Energy Information
Study Location | Auburn, New York |
---|---|
Site Description | Agricultural |
Study Type | Long-term Monitoring |
Technology | Internal Combustion Engine |
Prime Mover | Caterpillar G3508 |
Heat Recovery Systems | Built-in |
Fuel | Biogas |
System Installer | RCM Digesters |
System Enclosure | Outdoor |
System Application | Combined Heat and Power |
Number of Prime Movers | 1 |
Stand-alone Capability | Seamless |
Power Rating | 180 kW0.18 MW <br />180,000 W <br />180,000,000 mW <br />1.8e-4 GW <br />1.8e-7 TW <br /> |
Nominal Voltage (V) | 480 |
Heat Recovery Rating (BTU/hr) | 2000 |
Cooling Capacity (Refrig/Tons) | |
Origin of Controller | Manufacturer-Integrated |
Component Integration | Factory Integrated |
Start Date | 2006/03/10 |
Monitoring Termination Date | 1969/12/31 |
Primary Power Application | Based Load |
Secondary Power Application | |
Primary Heat/Cooling Application | Other |
Secondary Heat/Cooling Application | Other |
Capacity Factor | .897 |
Availability | 99.93 |
Electrical Efficiency (HHV) | |
Electrical Efficiency (LHV) | |
Highest Combustion Intake Air Temperature (F) | 108.3°F315.539 K <br />42.389 °C <br />567.97 °R <br /> |
Lowest Combustion Intake Air Temperature (F) | 7.8°F259.706 K <br />-13.444 °C <br />467.47 °R <br /> |
NOx Emissions Data Available | No |
CO Emissions Data Available | No |
12-Month Run Hours | 17104 |
12-Month Energy Savings (USD) | |
System Cost (USD) | |
Report URL | http://chp.nyserda.org/facilities/details.cfm?facility=70 |
Study Verified | Yes |