2-ft Flume Facility

From Open Energy Information


Basic Specifications
Overseeing Organization United States Army Corp of Engineers (ERDC)
Hydrodynamic Testing Facility Type Flume


Length(m) 61
Beam(m) 0.6
Depth(m) 1.8
Water Type Freshwater


Participation in TEAMER
TEAMER Facility No



Towing Capabilities
Towing Capabilities None


Wavemaking Capabilities
Wavemaking Capabilities Yes
Maximum Wave Height(m) 0.6
Maximum Wave Height(m) at Wave Period(s) 10
Wave Period Range(s) 10
Current Velocity Range(m/s) 0
Programmable Wavemaking Yes


Simulated Beach No
Channel/Tunnel/Flume
Channel/Tunnel/Flume Yes


Wind Capabilities
Wind Capabilities None


Control and Data Acquisition
Description Automated data acquisition and control system


Cameras None


Available Sensors Flow, Pressure Range(psi), Turbulence, Velocity, Wave Probe
Data Generation Capability
Real-Time No


Test Services
Past Pertinent Test Experience Studies done for Yaquina, WA, RIB floating breakwater, generalized Core-Loc stability tests, Cresent City, CA, generalized dolos structural tests, jetty stability
Special Characteristics
Special Characteristics None


Hydro | Hydrodynamic Testing Facilities