Property:Incentive/EquipReqs
From Open Energy Information
Property Name | Incentive/EquipReqs |
---|---|
Property Type | Text |
Description | Equipment Requirements. |
J
'''Electric'''<br>
All appliances must be Energy Star <br>
Electric Water Heater: 0.86 EF or greater <br>
Central AC: SEER 14, EER 11 minimum<br>
Air Source Heat Pump: SEER 14 or greater<br>
<br> '''Natural Gas'''<br>
Furnace: AFUE 95% or greater<br>
Boiler: AFUE 85% or greater<br>
Natural Gas Water Heater: EF 0.67 or greater<br> +
F
Focus on Energy - Efficient Heating and Cooling Cash-Back Rewards (WPS Customers Only) (Wisconsin) +
'''Gas Furnace (natural gas, LP/propane, or oil):''' 90% AFUE or greater; variable-speed motor/ECM; multiple stages of firing<br> '''Natural Gas Hot-Water Boiler:'''90% AFUE or greater; modulating burner; outdoor-air reset control +
S
'''PV''': New, grid connected; modules must be UL 1703 listed; inverters must be UL 1741-listed or listed by another nationally recognized testing laboratory.<br> '''Solar water heating''': New equipment; collectors must have an OG-100 output rating from SRCC or an equivalent organization. <br>
All systems: 5-year warranty required on major system components and installation, with the exception of batteries, for which a 2-year warranty is required. +
A
'''Residential'''<br/>Furnaces: minimum of 92% AFUE rating<br>
Boiler: minimum of 84% AFUE rating<br>
Hot Water Heaters: minimum EF of 62 (tank); 82 (tankless)<br>
Programmable Thermostat: must be Energy Star<br/><br/>
'''Commercial'''<br/>
Infrared Heating: 92% Combustion Efficiency<br/>
Boilers (Non-Condensing): 85%+<br/>
Boilers (Condensing): 92% AFUE<br/>
Fryers: ENERGY STAR, 50% Efficiency<br/>
Cooking Equipment: Varies +
C
'''Solar PV:''' System must be professionally designed and installed, and equipment (inverter and
modules) must be listed by California Solar Initiative (www.gosolarcalifornia.org/links/equipment_links). System must be warranted as follows: min. 20 years for solar modules, min. 5 years for inverter, min. 1 year for installation. <br> '''Wind Generators:''' System must be professionally designed and installed, and equipment must have UL
certificate of compliance (UL 6140; UL 1741). System must be warranted as follows: min. 5 years for
generator, min. 1 year for installation +
N
'''Solar:'''<br>
Systems must be in compliance with all applicable standards; Must carry a minimum 7-year warranty on inverters, 20-year warranty on panels, and 2-year warranty on labor; Modules and inverters must be on the California Energy Commission (CEC) approved equipment list.<br> '''Wind:'''<br>
Turbines with a swept area smaller than 200 m2 must be listed by the Interstate Turbine Advisory Council. Turbines with a swept area greater than 200 m2 must have an IEC 61400-12 (power curve) certification provided.<br>
proposed installation location must
The proposed location must have an average annual wind speed of 10 miles per hour or greater at the hub height of the turbine.
<br> '''Hydro:'''<br>
Systems must be in compliance with all applicable standards and under 200kW. +
A
S
1,500 cost share +
N
10 new buildings in 2004 +
C
R
2 MW or greater, or for expansions of 1 MW or greater +
F
2-year installation warranty and 1-year equipment warranty required for renewable energy systems; A system performance meter with an uncertainty of no more than 5% must be included in electric generating systems; See solicitations for other requirements +
C
20 MW or less: thermal efficiency of 65% or greater<br>
Larger than 20 MW: thermal efficiency of 70% or greater +
S
20 kW maximum of photovoltaics in each school district +
I
24 Program Requirements on the Lighting Incentives Application denote equipment eligibility. +
C
5 megawatts or less +
T
50 kW minimum for solar power, 1 MW minimum for wind power, biomass, landfill gas, hydropower or similar resource<br>
Minimum Capital Investment for a renewable energy facility: 1,000,000 +
W
50% cost-share required +
50% matching funds +
D
65 MW maximum capacity +