EGS Collab Daily Shift Report

 

Date:  08/05/2019

Written by: John Carlo Primo (jprimo@asu.edu, tel.: 605-580-5041)

SURF Personnel:

Location(s): 4850 West Drift

 

Summary:

 

Planned Tasks: Inspection of chiller and Kloehn pump maintenance.

 

·      Caged down at 7:00 am.

·      A quick inspection of the overall condition of the site and equipment was done before proceeding to do planned tasks.

·      The Kloehn pump was shut off. The old and leaky syringe was removed and replaced with a new one. After that, the pump was turned back on.

·      The flow rate from the outlet tube was then measured using a graduated cylinder and a cellphone timer. The flow rate was measured twice. The initial measurement after replacing the pump syringe was 85 mL/min. The second measurement read at 80 mL/min. and was taken an hour after the initial measurement. The normal flow rate is usually at 250 mL/min. A blockage inside the inlet tube was suspected. Further troubleshooting required on the next underground trip.

·      Chiller was working during the initial inspection and had an outlet temperature of 7.9 °C. It started malfunctioning around 9:00 am. It was reset twice but kept malfunctioning and was shut off at the end of the shift. Further maintenance required tomorrow.

·      Troubleshooting of Kloehn pump and Chiller was coordinated with Hunter Knox and Christopher Strickland.

·      Caged up at 11:45 am.

 

Lead Researcher: 

 

Documents or Procedures: 

 

Inspections:

 

Materials Receiving/Shipping: N/A

 

Comments: None

 

Recommendations: N/A.

 

Irregularities: Chiller malfunctioned.

 

Acts of Safety:  Actively worked on preventing slips, trips, and falls.

 

Near Misses or Incidents:  N/A

 

 

 

 

 

 

EGS Collab Personnel Hours (Surface and Underground):

 

 

Name

Surface Hours

Underground Hours

Time In

Time Out

Time In

Time Out

1

John Carlo Primo (Sigma V)

6:30 am

12:00 pm

7:00 am

11:45 am

 

 

 

 

 

 


Toolbox Form

8 5 19 1.png

Old Kloehn Pump Syringe


8 5 19 2.png

 

Kloehn Pump with new syringe installed

 

8 5 19 3.png

 

Chiller Malfunctioning

8 5 19 4.png