Browse wiki

From Open Energy Information

Sweden Building 05K0044
Building/Boundaries One building  +
Building/Category Office  +
Building/County Stockholm County, Sweden: Energy Resources +
Building/EndPeriod July 1, 2005  +
Building/FloorAreaMiscellaneous 1,234  +
Building/FloorAreaOffices 3,948  +
Building/FloorAreaTheatresConcertHallsCinemas 844  +
Building/FloorAreaTotal 6,026  +
Building/InteriorHeight 5  +
Building/MeanAnnualTempAtSite 6.6  +
Building/MeanAnnualTempCalculationPeriod 7.825  +
Building/Oid 7,096  +
Building/OwnershipCategory Government building  +
Building/SPBreakdownOfElctrcityUseKwhM2AirCompressors 0.0  +
Building/SPBreakdownOfElctrcityUseKwhM2CirculationFans 0.0  +
Building/SPBreakdownOfElctrcityUseKwhM2Copiers 1.87436676798  +
Building/SPBreakdownOfElctrcityUseKwhM2ElctrcEngineHeaters 0.0  +
Building/SPBreakdownOfElctrcityUseKwhM2ElctrcHeating 0.0  +
Building/SPBreakdownOfElctrcityUseKwhM2Elevators 5.97411218055  +
Building/SPBreakdownOfElctrcityUseKwhM2Fans 29.2053648476  +
Building/SPBreakdownOfElctrcityUseKwhM2HeatPumps 0.0  +
Building/SPBreakdownOfElctrcityUseKwhM2HeatPumpsUsedForColg 0.0  +
Building/SPBreakdownOfElctrcityUseKwhM2LargeComputersServers 0.0  +
Building/SPBreakdownOfElctrcityUseKwhM2LargeKitchens 0.0  +
Building/SPBreakdownOfElctrcityUseKwhM2Laundry 0.0  +
Building/SPBreakdownOfElctrcityUseKwhM2Lighting 30.8744894997  +
Building/SPBreakdownOfElctrcityUseKwhM2Misc 1.07625622777  +
Building/SPBreakdownOfElctrcityUseKwhM2Pcs 4.62831813576  +
Building/SPBreakdownOfElctrcityUseKwhM2Printers 0.497467071935  +
Building/SPBreakdownOfElctrcityUseKwhM2Pumps 3.03758154663  +
Building/SPBreakdownOfElctrcityUseKwhM2Refrigeration 0.0  +
Building/SPBreakdownOfElctrcityUseKwhM2SmallKitchensCoffeeRms 1.70972644377  +
Building/SPBreakdownOfElctrcityUseKwhM2Total 78.8776827217  +
Building/SPElectrtyUsePercAirCompressors 0.0  +
Building/SPElectrtyUsePercCirculationFans 0.0  +
Building/SPElectrtyUsePercCopiers 2.37629542769  +
Building/SPElectrtyUsePercElctrcEngineHeaters 0.0  +
Building/SPElectrtyUsePercElctrcHeating 0.0  +
Building/SPElectrtyUsePercElevators 7.57389412875  +
Building/SPElectrtyUsePercFans 37.0261445821  +
Building/SPElectrtyUsePercHeatPumps 0.0  +
Building/SPElectrtyUsePercHeatPumpsUsedForColg 0.0  +
Building/SPElectrtyUsePercLargeComputersServers 0.0  +
Building/SPElectrtyUsePercLargeKitchens 0.0  +
Building/SPElectrtyUsePercLaundry 0.0  +
Building/SPElectrtyUsePercLighting 39.1422369857  +
Building/SPElectrtyUsePercMisc 1.36446227962  +
Building/SPElectrtyUsePercPcs 5.86771565297  +
Building/SPElectrtyUsePercPrinters 0.630681651349  +
Building/SPElectrtyUsePercPumps 3.85100251658  +
Building/SPElectrtyUsePercRefrigeration 0.0  +
Building/SPElectrtyUsePercSmallKitchensCoffeeRms 2.16756677526  +
Building/SPElectrtyUsePercTotal 100.0  +
Building/SPPurchasedEngyForPeriodMwhYrDigesterLandfillGas 0.0  +
Building/SPPurchasedEngyForPeriodMwhYrDstrtColg 81.0  +
Building/SPPurchasedEngyForPeriodMwhYrDstrtHeating 374.0  +
Building/SPPurchasedEngyForPeriodMwhYrElctrtyTotal 452.0  +
Building/SPPurchasedEngyForPeriodMwhYrLogs 0.0  +
Building/SPPurchasedEngyForPeriodMwhYrNaturalGas 0.0  +
Building/SPPurchasedEngyForPeriodMwhYrOil-FiredBoiler 0.0  +
Building/SPPurchasedEngyForPeriodMwhYrOther 0.0  +
Building/SPPurchasedEngyForPeriodMwhYrPellets 0.0  +
Building/SPPurchasedEngyForPeriodMwhYrTotal 907.0  +
Building/SPPurchasedEngyForPeriodMwhYrTownGas 0.0  +
Building/SPPurchasedEngyForPeriodMwhYrWoodChips 0.0  +
Building/SPPurchasedEngyNrmlYrMwhYrDigesterLandfillGas 0.0  +
Building/SPPurchasedEngyNrmlYrMwhYrDstrtColg 81.0  +
Building/SPPurchasedEngyNrmlYrMwhYrDstrtHeating 399.0  +
Building/SPPurchasedEngyNrmlYrMwhYrElctrtyTotal 452.0  +
Building/SPPurchasedEngyNrmlYrMwhYrLogs 0.0  +
Building/SPPurchasedEngyNrmlYrMwhYrNaturalGas 0.0  +
Building/SPPurchasedEngyNrmlYrMwhYrOil-FiredBoiler 0.0  +
Building/SPPurchasedEngyNrmlYrMwhYrOther 0.0  +
Building/SPPurchasedEngyNrmlYrMwhYrPellets 0.0  +
Building/SPPurchasedEngyNrmlYrMwhYrTotal 932.0  +
Building/SPPurchasedEngyNrmlYrMwhYrTownGas 0.0  +
Building/SPPurchasedEngyNrmlYrMwhYrWoodChips 0.0  +
Building/SPPurchasedEngyPerAreaKwhM2DigesterLandfillGas 0.0  +
Building/SPPurchasedEngyPerAreaKwhM2DstrtColg 13.4417524062  +
Building/SPPurchasedEngyPerAreaKwhM2DstrtHeating 66.2130766678  +
Building/SPPurchasedEngyPerAreaKwhM2ElctrcHeating 0.0  +
Building/SPPurchasedEngyPerAreaKwhM2ElctrtyTotal 75.008297378  +
Building/SPPurchasedEngyPerAreaKwhM2Logs 0.0  +
Building/SPPurchasedEngyPerAreaKwhM2NaturalGas 0.0  +
Building/SPPurchasedEngyPerAreaKwhM2Oil-FiredBoiler 0.0  +
Building/SPPurchasedEngyPerAreaKwhM2Other 0.0  +
Building/SPPurchasedEngyPerAreaKwhM2OtherElctrty 75.008297378  +
Building/SPPurchasedEngyPerAreaKwhM2Pellets 0.0  +
Building/SPPurchasedEngyPerAreaKwhM2Total 154.663126452  +
Building/SPPurchasedEngyPerAreaKwhM2TownGas 0.0  +
Building/SPPurchasedEngyPerAreaKwhM2WoodChips 0.0  +
Building/StartPeriod August 1, 2004  +
Building/TotalFloorArea 6,026  +
Building/YearConstruction 1878  +
Building/YearConstruction1 1970  +
Building/YearConstruction2 1878  +