Browse wiki

From Open Energy Information

Sweden Building 05K0007
Building/Boundaries One building  +
Building/Category Office  +
Building/County Stockholm County, Sweden: Energy Resources +
Building/EndPeriod September 1, 2005  +
Building/FloorAreaHeatedGarages 400  +
Building/FloorAreaOffices 21,765  +
Building/FloorAreaRestaurants 1,990  +
Building/FloorAreaTotal 24,155  +
Building/InteriorHeight 3.5  +
Building/MeanAnnualTempAtSite 6.6  +
Building/MeanAnnualTempCalculationPeriod 7.733  +
Building/Oid 25,162  +
Building/OwnershipCategory Government building  +
Building/SPBreakdownOfElctrcityUseKwhM2AirCompressors 0.0  +
Building/SPBreakdownOfElctrcityUseKwhM2CirculationFans 2.02541916787  +
Building/SPBreakdownOfElctrcityUseKwhM2Copiers 0.897811865554  +
Building/SPBreakdownOfElctrcityUseKwhM2ElctrcEngineHeaters 0.0  +
Building/SPBreakdownOfElctrcityUseKwhM2ElctrcHeating 0.0  +
Building/SPBreakdownOfElctrcityUseKwhM2Elevators 0.699648105982  +
Building/SPBreakdownOfElctrcityUseKwhM2Fans 8.3953561818  +
Building/SPBreakdownOfElctrcityUseKwhM2HeatPumps 0.0  +
Building/SPBreakdownOfElctrcityUseKwhM2HeatPumpsUsedForColg 0.0  +
Building/SPBreakdownOfElctrcityUseKwhM2LargeComputersServers 11.4098804421  +
Building/SPBreakdownOfElctrcityUseKwhM2LargeKitchens 3.38701556508  +
Building/SPBreakdownOfElctrcityUseKwhM2Laundry 0.0  +
Building/SPBreakdownOfElctrcityUseKwhM2Lighting 16.0796522459  +
Building/SPBreakdownOfElctrcityUseKwhM2Misc 12.9530389597  +
Building/SPBreakdownOfElctrcityUseKwhM2Pcs 5.8172794947  +
Building/SPBreakdownOfElctrcityUseKwhM2Printers 1.12158808933  +
Building/SPBreakdownOfElctrcityUseKwhM2Pumps 1.66724551261  +
Building/SPBreakdownOfElctrcityUseKwhM2Refrigeration 0.0  +
Building/SPBreakdownOfElctrcityUseKwhM2SmallKitchensCoffeeRms 1.08639747349  +
Building/SPBreakdownOfElctrcityUseKwhM2Total 65.5403331042  +
Building/SPElectrtyUsePercAirCompressors 0.0  +
Building/SPElectrtyUsePercCirculationFans 3.09034005771  +
Building/SPElectrtyUsePercCopiers 1.36986161503  +
Building/SPElectrtyUsePercElctrcEngineHeaters 0.0  +
Building/SPElectrtyUsePercElctrcHeating 0.0  +
Building/SPElectrtyUsePercElevators 1.06750770532  +
Building/SPElectrtyUsePercFans 12.809449974  +
Building/SPElectrtyUsePercHeatPumps 0.0  +
Building/SPElectrtyUsePercHeatPumpsUsedForColg 0.0  +
Building/SPElectrtyUsePercLargeComputersServers 17.4089448462  +
Building/SPElectrtyUsePercLargeKitchens 5.16783391945  +
Building/SPElectrtyUsePercLaundry 0.0  +
Building/SPElectrtyUsePercLighting 24.5339800461  +
Building/SPElectrtyUsePercMisc 19.7634622014  +
Building/SPElectrtyUsePercPcs 8.87587721816  +
Building/SPElectrtyUsePercPrinters 1.71129445978  +
Building/SPElectrtyUsePercPumps 2.54384656538  +
Building/SPElectrtyUsePercRefrigeration 0.0  +
Building/SPElectrtyUsePercSmallKitchensCoffeeRms 1.65760139145  +
Building/SPElectrtyUsePercTotal 100.0  +
Building/SPPurchasedEngyForPeriodMwhYrDigesterLandfillGas 0.0  +
Building/SPPurchasedEngyForPeriodMwhYrDstrtColg 450.0  +
Building/SPPurchasedEngyForPeriodMwhYrDstrtHeating 1448.0  +
Building/SPPurchasedEngyForPeriodMwhYrElctrtyTotal 1487.0  +
Building/SPPurchasedEngyForPeriodMwhYrLogs 0.0  +
Building/SPPurchasedEngyForPeriodMwhYrNaturalGas 0.0  +
Building/SPPurchasedEngyForPeriodMwhYrOil-FiredBoiler 0.0  +
Building/SPPurchasedEngyForPeriodMwhYrOther 0.0  +
Building/SPPurchasedEngyForPeriodMwhYrPellets 0.0  +
Building/SPPurchasedEngyForPeriodMwhYrTotal 3385.0  +
Building/SPPurchasedEngyForPeriodMwhYrTownGas 0.0  +
Building/SPPurchasedEngyForPeriodMwhYrWoodChips 0.0  +
Building/SPPurchasedEngyNrmlYrMwhYrDigesterLandfillGas 0.0  +
Building/SPPurchasedEngyNrmlYrMwhYrDstrtColg 450.0  +
Building/SPPurchasedEngyNrmlYrMwhYrDstrtHeating 1542.0  +
Building/SPPurchasedEngyNrmlYrMwhYrElctrtyTotal 1487.0  +
Building/SPPurchasedEngyNrmlYrMwhYrLogs 0.0  +
Building/SPPurchasedEngyNrmlYrMwhYrNaturalGas 0.0  +
Building/SPPurchasedEngyNrmlYrMwhYrOil-FiredBoiler 0.0  +
Building/SPPurchasedEngyNrmlYrMwhYrOther 0.0  +
Building/SPPurchasedEngyNrmlYrMwhYrPellets 0.0  +
Building/SPPurchasedEngyNrmlYrMwhYrTotal 3479.0  +
Building/SPPurchasedEngyNrmlYrMwhYrTownGas 0.0  +
Building/SPPurchasedEngyNrmlYrMwhYrWoodChips 0.0  +
Building/SPPurchasedEngyPerAreaKwhM2DigesterLandfillGas 0.0  +
Building/SPPurchasedEngyPerAreaKwhM2DstrtColg 18.6296832954  +
Building/SPPurchasedEngyPerAreaKwhM2DstrtHeating 63.8377147588  +
Building/SPPurchasedEngyPerAreaKwhM2ElctrcHeating 0.0  +
Building/SPPurchasedEngyPerAreaKwhM2ElctrtyTotal 61.5607534672  +
Building/SPPurchasedEngyPerAreaKwhM2Logs 0.0  +
Building/SPPurchasedEngyPerAreaKwhM2NaturalGas 0.0  +
Building/SPPurchasedEngyPerAreaKwhM2Oil-FiredBoiler 0.0  +
Building/SPPurchasedEngyPerAreaKwhM2Other 0.0  +
Building/SPPurchasedEngyPerAreaKwhM2OtherElctrty 61.5607534672  +
Building/SPPurchasedEngyPerAreaKwhM2Pellets 0.0  +
Building/SPPurchasedEngyPerAreaKwhM2Total 144.028151521  +
Building/SPPurchasedEngyPerAreaKwhM2TownGas 0.0  +
Building/SPPurchasedEngyPerAreaKwhM2WoodChips 0.0  +
Building/StartPeriod October 1, 2004  +
Building/TotalFloorArea 24,155  +
Building/YearConstruction 1900  +
Building/YearConstruction1 1972  +
Building/YearConstruction2 1900  +
Categories Sweden Buildings
Modification date
"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by Semantic MediaWiki.
01:51:29, 5 June 2010  +
hide properties that link here 
  No properties link to this page.
 
Enter the name of the page to start browsing from.