Browse wiki

From Open Energy Information

Distributed Generation Study/VIP Country Club
Capacity 0.18 MW (180 kW, 180,000 W, 180,000,000 mW, 1.8e-4 GW, 1.8e-7 TW, 1.8e-10 PW, 1.8e-13 EW, 1.8e-16 ZW)  +
Combustion Intake Air Temperature 297.039 K (23.889 °C, 75 °F, 534.67 °R)  + , 291.483 K (18.333 °C, 65 °F, 524.67 °R)  +
Component Integration Factory Integrated  +
Distributed Generation/Site Description Commercial-Other  +
Distributed Generation Prime Mover Capstone C60 +
Distributed Generation System Application Combined Heat and Power +
Distributed Generation System Enclosure Indoor  +
Distributed Generation System Heating-Cooling Application Domestic Hot Water + , Space Heat and/or Cooling +
Distributed Generation System Power Application Based Load +
Fuel Natural Gas +
Heat Recovery Rating 750,000  +
Heat Recovery Systems Built-in +
Nominal Voltage 480  +
Number of Prime Movers 3  +
Organizations Advanced Power Systems +
Origin of Controller Manufacturer-Integrated  +
Place New Rochelle, New York: Energy Resources +
Stand-alone Capability Seamless  +
Study Type Long-term Monitoring +
Technology Microturbine +
Categories Distributed Generation Studies
Modification date
"Modification date" is a predefined property that corresponds to the date of the last modification of a subject and is provided by Semantic MediaWiki.
22:50:05, 24 January 2013  +