Difference between revisions of "MHK ISDB/Instruments/InterOcean 902 Acoustic Listening and Calibration System"
From Open Energy Information
< MHK ISDB
(Created page with "{{MHK_Instrument
|Name=InterOcean 902 Acoustic Listening and Calibration System
|Abbreviation=
|Deployment=Field
|OperatingEnvironment=Underwater
|MeasurementType=Acousti...") |
(Add measurement value) |
||
Line 1: | Line 1: | ||
− | {{ | + | {{MHK Instrument |
|Name=InterOcean 902 Acoustic Listening and Calibration System | |Name=InterOcean 902 Acoustic Listening and Calibration System | ||
− | | | + | |Abstract=The Model 902 Underwater Acoustic Listening and Calibration System is a portable instrument designed to provide the user with a convenient means to record and to make calibrated measurements of underwater sound sources. The Model 902 comes complete with a sensitive hydrophone with 15 meters of cable, headphones and an output jack to permit recording of the underwater sounds. |
+ | |ImageLink=http://www.interoceansystems.com/images/transducers/902_2_200.jpg | ||
|Deployment=Field | |Deployment=Field | ||
|OperatingEnvironment=Underwater | |OperatingEnvironment=Underwater | ||
− | |MeasurementType=Acoustic Noise | + | |MeasurementType=Acoustic Noise, Animal Monitoring |
− | |MeasurementAttribute=Sound Pressure | + | |MeasurementAttribute=Sound Pressure, Animal Detection, Animal Identification |
− | + | |Measurement=Sound Pressure Level (Sound Pressure), Presence (Animal Detection), Vocalization (Animal Detection), Vocalization (Animal Identification) | |
− | |Measurement=Sound Pressure Level (Sound Pressure) | + | |MeasurementSpecification=Frequency response: 20 Hz to 10 kHz <br> Nominal Sensitivity: 100 dB (+-3 dB) re 1 uPa RMS Pressure |
− | |||
− | |MeasurementSpecification=Frequency response: 20 Hz to 10 kHz | ||
− | Nominal Sensitivity: 100 dB (+-3 dB) re 1 uPa RMS Pressure | ||
− | |||
− | |||
|CommProtocol=Internal Logging | |CommProtocol=Internal Logging | ||
|OperatingMode=Free Streaming, Stand Alone | |OperatingMode=Free Streaming, Stand Alone | ||
− | + | |PowerSupplyType=Battery, VDC | |
− | |PowerSupplyType=VDC | ||
|PowerSpec=9 VDC; 6x D cell | |PowerSpec=9 VDC; 6x D cell | ||
− | |||
|Organization=InterOcean Systems Inc. | |Organization=InterOcean Systems Inc. | ||
|Website=http://www.interoceansystems.com/transducer_902.htm | |Website=http://www.interoceansystems.com/transducer_902.htm | ||
|Specpage=http://www.interoceansystems.com/transducer_902.htm | |Specpage=http://www.interoceansystems.com/transducer_902.htm | ||
− | | | + | |MeasurementAttributeOptional= |
− | | | + | |MeasurementOptional= |
− | |||
− | |||
|Experience= | |Experience= | ||
}} | }} |
Latest revision as of 12:26, 21 June 2016
InterOcean 902 Acoustic Listening and Calibration System
Manufacturer: InterOcean Systems Inc.
Measurement Category: Acoustic Noise, Animal Monitoring
Operating Environment: Underwater
Communication Protocol: Internal Logging
Operating Mode: Free Streaming, Stand Alone
Power Supply Type: Battery, VDC
Power Specification: 9 VDC; 6x D cell
Description
The Model 902 Underwater Acoustic Listening and Calibration System is a portable instrument designed to provide the user with a convenient means to record and to make calibrated measurements of underwater sound sources. The Model 902 comes complete with a sensitive hydrophone with 15 meters of cable, headphones and an output jack to permit recording of the underwater sounds.
Instrument Measurements
- Sound Pressure Level (Sound Pressure)
- Presence (Animal Detection)
- Vocalization (Animal Detection)
- Vocalization (Animal Identification)
Measurement Specifications
Frequency response: 20 Hz to 10 kHz
Nominal Sensitivity: 100 dB (+-3 dB) re 1 uPa RMS Pressure
Notes, Considerations & Recommendations
User Experience